RIAT+
Basic Information
Language
English
Latest update
Price
Free of charge after accepting "end user license agreement" (EULA).
Application time
With all input data, running time is limited to a few minutes. Preparing of all input data can take a long time, more than one month
Assistance required
It is not mandatory but strongly advised
Assistance data
Measure DB (GAINS Technologies), Regional emission data, Source/Receptors Functions
Tool type
Method / Approach Software
Application area
- Analysis, scenarios and measure selection
Target Audience
- Metropolitan regions
- Other
Summary
RIAT+ is a regional Integrated Assessment Modelling tool developed during the OPERA project (LIFE09 ENV/IT/000092). It has been designed to help regional decision makers to select optimal air pollution reduction policies that will improve the air quality at minimum costs.
The system incorporates explicitly the specific features of the area of interest with regional input data-set for the:
- precursor emissions of local and surrounding sources;
- abatement measures described per activity sector and technology with information on application rates, emission removal efficiency factor and cost;
- effect of meteorology and prevailing chemical regimes through the use of site specific source-receptor (S/R) functions.
The tool allows two possible decision pathways: scenario analysis and optimization.
The main outputs from RIAT+ are a summary of emission reductions on the domain, a table of the application rates for the different measures, maps of a set of relevant air quality indexes (AQIs) and, for the optimisation pathway, the Pareto Curve providing the efficient solutions of a specific AQI ranked by costs.
The S/R model is used, internally, to link emissions to an AQI. The S/R model can be as simple as a linear relationship, or as complex as a chemical transport model. To limit the computational time, RIAT+ currently uses a nonlinear relations identified by means of Artificial Neural Networks (ANNs), tuned to replicate the results of a limited set of simulations performed by the users with deterministic air quality model calibrated on the specific site.
Good Example
Emilia-Romagna and Alsace Region were the first case studies used during Opera project to design and implement RIAT+ tool answering regional requirements in air quality planning. Afterwards RIAT+ was employed in "Progetto VALUTA" of ARPA Lombardia. Furthermore, RIAT+ has been exploited in the final step of the APPRAISAL project: it was the application of the IAM tool RIAT+ in two test cases, one in the Brussels Capital Region in Belgium and in the region of Porto in the North of Portugal.
Thematic areas
Integrated & inclusive planning
Contacts
Terraria srl with partner: Arpa Emilia Romagna, Università degli studi di Brescia, CNRS, Université de Strasbourg, JRC Ispra
riat [at] terraria.com
0039 0287085650